Matters needing attention for wiring harness maintenance of medical instruments and equipment

Date: 2021-03-30 Visited: 462

At present, the maintenance of medical equipment is a very complicated work, many medical institutions have equipment department, responsible for maintaining the safety and stability of equipment, but there are many problems that many equipment maintenance personnel do not understand or pay attention to. Here to everyone under the medical equipment wiring harness maintenance and maintenance.


The first point: meticulous daily maintenance, to ensure the normal operation of equipment is crucial.


Daily maintenance seems simple, but many times is not paid attention to, but also easy to ignore; But a lot of times big problems are compounded by small problems. To do with the clinical use of active cooperation, keep the surface of the instrument clean; Check whether the voltage and power supply are normal before use; During use, observe whether the function of the instrument is normal and fill in the use record. Develop good habits during routine maintenance to avoid damage.


Second point: equipment maintenance work, must be carefully handled, do not careless.


In case of equipment failure, information collection and preparation work should be done before maintenance. Including the model number, factory number, time of fault occurrence, abnormal sound when the fault occurs, whether there has been sudden power failure, whether the instrument has moved and other issues.


During maintenance, attention should be paid to the sequence of disassembly of medical equipment and do not force disassembly with brute force. Disassembled fastening screws, small pieces, etc., can not be conveniently placed, to be classified to avoid loss. After the completion of equipment maintenance, installation, and then in reverse order step by step to restore the original, no redundant accessories. The damaged parts should also be marked and restored to their original appearance after replacement, without any mistakes.


After the maintenance work is completed, clean the surface of the instrument, connect the power supply, to see if it can work normally. Calibrate the instrument to return to normal working state, and then hand it over to the user for trial to check whether the instrument is restored to the original working state, so as to avoid leaving hidden dangers. After cleaning the site, check whether there are missing tools, and fill in the maintenance log for future reference.


The protection engineer in maintenance should always pay attention to the protection work when maintaining the instrument, whether it is leakage or cross infection and other problems, should pay attention to the protection. Don't cause unnecessary injuries.


Third point: regular maintenance inspection, problems found as soon as possible, as soon as possible to solve.


Detailed preventive maintenance should include:


Appearance inspection: first of all, check whether the buttons, switches, joints and sockets of the instrument are loose and misplaced, whether the contact of plugs and sockets is oxidizing, rusting or poor contact, whether the power line is aging, whether the heat dissipation and exhaust air are normal, whether the connection of all kinds of grounding and pipe is good.


Cleaning and maintenance: it is to clean the electrical and mechanical parts of the surface and the internal parts of the instrument, including cleaning the filter screen and the relevant pipes, cleaning the relevant plugs and sockets of the instrument, to prevent bad contact, and lubricating the necessary mechanical parts.


Replacement of wearing parts: to have reached the service life and performance decline, substandard components or parts required to be replaced regularly as specified in the operation manual to timely replace, to prevent the possible expansion of the fault or cause the machine failure. In the case of insufficient battery charging, the relevant personnel should be urged to charge regularly, and all kinds of obvious and potential faults of the equipment should be eliminated.


Performance test calibration: test the voltage stability value of each DC power supply, the voltage value or waveform to be tested in the circuit, and make necessary calibration and adjustment according to the requirements of the manual, in order to ensure that the technical indicators of the instrument meet the standards, to ensure the quality of the instrument in medical diagnosis and treatment.


Safety check: 1. Check whether the frame is firm, whether the mechanical operation is normal, and whether the connecting parts are loose, fall off or rupture. 2. Check whether various leads, plugs and connectors are damaged, whether the grounding wire is firm, and whether the grounding resistance and leakage current are within the allowable limit.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
主站蜘蛛池模板: 波多野结衣一区二区三区在线观看 | 草的爽免费视频 | 大妹子最新视频在线观看 | 成人免费大片黄在线观看com | 国产精品亚洲自在线播放页码 | 不卡一级毛片免费高清 | 牛牛a级毛片在线播放 | 精品免费视在线观看 | 精品在线免费播放 | 乱子伦一级在线观看高清 | 久久aa毛片免费播放嗯啊 | 国产乱淫视频 | 久热福利 | 国产免费播放一区二区 | 国产在线精彩视频 | 国产免费叼嘿网站免费 | 国产熟睡乱子伦视频观看看 | 国产成年美女毛片80s | 国产91在线免费观看 | 国产在播放一区 | 国产中文字幕第一页 | 麻豆女教师 | 波多野结衣在线播放视频 | 鲁在线视频| 国产普通话自拍 | 久久国产三级精品 | 久久久久免费精品视频 | 久久99国产精品二区不卡 | 免费一级淫片 | 国产农村一级特黄α真人毛片 | 久久综久久美利坚合众国 | 国产97在线视频观看 | 精品国产999 | 岛国在线永久免费视频 | 成 人 黄 色视频免费播放 | 久久久高清国产999尤物 | 精品999久久久久久中文字幕 | 男女做视频网站免费观看 | 国产区成人综合色在线 | 国产精品9999久久久久仙踪林 | 国产青榴社区91精品 |